In this position the tanks switch lower piston and the control valve moves to the backwash position upper. For electronic valves, please refer to the manual regeneration part of the timer operation section. Figure 5 figure 6 next, place the fleck 5600 meter valve onto the top of the tank, being sure. Ensure water goes into the brine tank at the desired rate. Calculate the desired salt setting using the brine line flow control rate of refill in gpm multiplied by the timer. Manually index the control to the brine draw position and allow the control to draw water from the brine tank until it stops.
This combination spells success for residential water conditioning dealers. Fleck manuals water softeners control heads set up and. Plug in the electrical cord and look in the sight hole in the back of the motor to see that it is. Fleck manuals water softeners control heads set up and repair instructions. Turn manual knob so that the micro switch rides on the first set of pins. Fleck control valves are available in timeclock option which can be set to regenerate every day, every two to three days, or on certain days of. Fleck valves are also available in metered options for ondemand regeneration based on the volume of water that has been used. Check the drain line flow, and run for 5 minutes or until the water. Installation instructions for backwashing systems with fleck 5600 and 5600sxt. Ensure the unit is drawing water from the brine tank this step may need to be repeated.
Series 5600 ecominder water softeners owners manual. On mechanical valves, turn the main knob until it clicks into the first position. It covers a wide range of applications either for softening or filtration purposes. Covers air injection silver, gold, and platinum filter systems. If power fails while the unit is in regeneration, the control will save the current valve position before it shuts down. This manual is intended as a guide for service of the valve only. Manually index the softener control into service position and let water. Position the valve to the start of the brine tank fill cycle. See how we can help you in your home or business, for life. The manufacturer reserves the right to make changes at any time without notice. Program the valve control according to instructions shown in this manual. It will be important to know what your waters hardness and iron content is before doing this programming procedure. Fleck 2510 sxt aio digital control valve with oxygen.
With proper installation and a little routine maintenance your system will be providing filtered water for many years. This video shows you how to set the system through an immediate regeneration. The use of other types of lubricants may attack the controls plastic or rubber components. Fleck 5600 filter and softener control valve pure water.
Solder joints near the drain must be done prior to connecting the drain line flow. Scope of the documentation the documentation provides the necessary informatio n for appropriate use of the product. Fleck parts for water softener and filter control valves 5600, 1500, 2500, 2510, 2750, 3600, 9000, 9100 and others. Programing the fleck 2510sxt metered valve water softener. It started to produce brine valves in 1958 and the first water softener valve in 1963. Fleck 2850 control valve service manual 16510 rev k oc11 table of contents.
Autotrol valves are for residential only and except for the magnum, are not suitable for commercial service. Supplemental service manual fleck systems valves and. This video walks you through programing the fleck 2510sxt metered valve that you purchased from. As treated water is used, the volume remaining display counts down in gallons from a maximum value to zero or. Control valves outfitted with an electromechanical timer and stainless steel water meter include a special male x female threaded stainless steel union to insure proper installation and operation of the water meter. Lubricate the distributor oring seal and tank oring seal. Petroleumbased lubricants can cause swelling in rubber parts, including orings and. Petroleumbased lubricants can cause swelling in rubber parts. In order to limit our teams exposure, we have reduced call center hours. The brine valve drive cam will hold the valve in this position to fill the brine tank for the first regeneration. Water softener parts, valves, and water filters fleck, ge osmonics autotrol, sears north star and other brands. Control operation during programming the control enters program mode with the valve in service.
The water softener should be installed with the inlet, outlet, and drain connections made in accordance with the manufacturers recommendations, and to meet applicable plumbing codes. Control programming is stored in memory permanently, eliminating the need for battery backup power. Model 900091009500 fleck systems valves and replacement parts. The pentair fleck 5800 control valves set a brand new standard for adaptability and innovative features. Make plumbing connections to the fleck 2850 sxt valve.
Silicone compound available from fleck, is recommended for best possible results. Let the water flow slowly into the mineral tank until the air is. Bypass valves always provide for the installation of a bypass valve if unit is. If the valve came with a separate electronic timer service manual, refer to the timer operation section of the electronic timer service manual. It is a good idea to allow the system to run through a manual cycle.
Do not use teflon tape or pipe dope on the valve or tank threads. Model 7000 service manual discount water softeners. Fleck 2815 xtr2 control valve manual pure aqua, inc. Air injection system fleck 2510 series installation. Fleck 2510 sxt control valve oxygen chamber system technology uses natural oxidation to remove iron, manganese and hydrogen sulfide from the water supply, without chemicals, without aerators, without air compressors, without venturies or loss of pressure. Control programming is stored in memory permanently. Fleck 5600 water filtration systems pdf manual download.
In this position the tanks switch lower piston and the control valve moves to. Manually index the control to the brine fill position and allow the brine tank to fill to the top of the air check. Compound available from fleck, is recommended for best possible results. Water softener identification how to identify the brand. Control operation during programming the control only enters the program mode with the valve in service. Fleck valves became a widelyused and nearlygeneric water softener control. Place the header in the service position and cycle the valve to the backwash position. Check the drain line flow, and run for 5 minutes or until the water runs clear. Control unit pentair fleck 5812 xtr2 service manual water softener or filter control valve 36 pages control unit pentair autotrol 604 installer manual. Wait until the positioning of upper and lower pistons stops before advancing the timer further.
Due to varying water conditions, tank sizes and water pressures, the above settings should be used only as a. These extremely durable valves have a time honored operating platform. Once we believe the manufacturer has gotten all the bugs out of the system, we may offer this valve as a more expensive alternative to the tried and true fleck 5600 valve analog models. System installation requires information from a number of suppliers not known.
Manually index the control to the backwash position and allow water to flow at the drain for 3 or 4 minutes. Next, place the fleck 2510sxt meter valve onto the top of the tank, being sure that the riser tube fits into the central oring on the valve, as shown in figure 7 below. Soldering of joints near the drain port must be done prior to connecting the drain line flow control fitting dlfc. Dow corning 7 release compound is used in the manufacture of fleck control valves. The location of this union in relation to the control valve and water meter is critical for proper operation.
The fleck 5600 econominder control valve was introduced to the market in 1980. The use of the number of pins multiplied by two equals minutes of other types of lubricants may attack the controls plastic or rubber components. Fleck 5810 series control valves high performance flexible 1 valve fleck 5810 control valve featuresbenefits fiberreinforced polymer valve body for superior strength and durability, noncorrosive, and uvresistant continuous service flow rate of 37 gpm with a backwash of 28 gpm backwash capability accommodates softener tanks up to 21 and. While in the program mode the control continues to operate normally monitoring water usage and keeping all displays up to date. Using the included silicone lubricant packet, lubricate the orings on the fleck 5600 meter valve as shown in figure 9 on the following page. While in the program mode, the control continues to operate normally monitoring water usage and keeping all displays up to date. Before startup a few simple steps must be followed to program the fleck 2510sxt meter valve. Finally, assemble the plumbing adaptor to the valve as shown in figure 10 on the following page. We like the engineered approach of helping you specify and purchase top of the line equipment. How to manually regenerate the fleck 5600 valve youtube.
Fleckenstein patented the original fleck closure, a quick and easy cover for water softener tanks. Unscrew by hand the entire fleck 5600 control valve from top of tank if it was shipped screwed on. View and download pentair fleck 5600 service manual online. Your new system comes with a printed fleck service manual, which along with this startup guide will help guide you in the. Make sure that the salt dosage is set as recommended by the manufacturer. On mechanical valves, turn the main knob until it clicks into the first.
System installation requires information from a number of suppliers not known at the time of manufacture. Finding information about programing your equipment 3. Hand tighten the valve to the tank snugly by hand only. The system is programmed to regenerate at 12 am or 2 am depending on. Fleck control valves automatically control the backwash and regeneration cycles for media filters and water softeners to keep your water treatment system working at optimal performance all the time. The control only enters the program mode with the valve in service. Service manuals for fleck control heads and valves provided by abundant flow water systems. In this position the tanks switch lower piston and the control valve moves to the backwash position upper piston. While in program mode the control continues to operate normally, monitoring water usage and keeping all displays up to date. Pentair offers a wide variety of products from pool and spa equipment, water filters, water pumps and spray nozzles. Let the water flow slowly into the mineral tank until the air is purged from the system. As an essential service, we continue to operate and serve our customers. Over the past decades, fleck has demonstrated a proven record of performance and reliability year after year. P fast positioning reversible 10,000 rpm 12 volt dc drive motor seal and spacer cartridge for easy servicing.
Fleck is one of the three brands of pentair control valves manufactured in emea region. Filtration valves residential water treatment products. The control valve has a separate brine tank fill cycle. Backwashing system fleck 5600 series installation instructions. Fleck 3900 control valves for water softeners and media filters. Leave at least 6 15 cm between the dlfc and solder joints when soldering pipes that are connected on the dlfc. Fleck 900091009500 service manual pure water products. Unscrew by hand the entire fleck 5600sxt control valve from top of tank if it was shipped screwed on. At the same time, they come from a company known for decades of expertise in the water industry, millions of units in service, and a tradition of rocksolid reliability. Installation instructions for air injection systems with fleck 2510 and 2510sxt. Currently fleck controls is owned by pentair water softeners link to pentair in this article fleckenstein, andrew j. Position the valve to the brine slow rinse position. Fleck 2815 control valve service manual 5 meter dome and union orientation control valves outfitted with an electromechanical timer and stainless steel water meter include a special male x female threaded stainless steel union to insure proper installation and operation of the water meter. View and download pentair fleck 2850 service manual online.
Fleck 3150 downflow service manual 3 installation water pressure a minimum of 20 pounds 1. Place distributor tube in tank if not already inside tank. Glass water systems believes these manuals are an excellent source for the following information. Visit our pdf library for technical specifications and product manuals on pentair autotrol valves. Fleck manuals water softeners control heads set up. Page 4 7 release compound is used in the pins at the higher numbered end of this section as required. Refer to the valve spec sheet for cutting height of the distributor tube. And we will start stocking the many unique valve parts that customer will be needed once their warranty has expired. Link to fleck accessories guide major parts and assemblies all models.
1118 861 320 1197 575 830 744 1112 142 554 89 1190 308 276 141 976 885 1090 1084 1520 1520 86 1107 1042 1042 197 1338 288 1034 752